When the On-Premise Poller loses internet connectivity, it continues to monitor your infrastructure and holds the collected data locally until the connection is restored. This article explains how the On-Premise Poller stores data during an outage, how it syncs the backlog afterward, and what limitations apply during prolonged outages.
Data collection during an outage
The On-Premise Poller continues data collection even when the network is unavailable. If the On-Premise Poller cannot reach Site24x7, the data collection (DC) is marked as a failed report, and the file is stored in the failed folder on disk instead of being discarded.
How long these files are retained depends on the device type:
- Network devices : Files are stored for as long as disk space is available on the machine. Once space runs out, new files can't be stored.
- Non-network devices : Files are stored for two days from the time the report is generated, after which they're purged. Outages that last longer than two days can cause data loss.
Once connectivity is restored, the On-Premise Poller uploads all the failed files using separate, dedicated threads. This upload runs in parallel and doesn't interfere with ongoing data collection. The data collection file (called reports) can be a maximum of 150 KB in size and can contain data collection data for one or more monitors.
General monitor data (excluding network monitors)
The sync duration depends on how long the outage lasted and how much backlog has built up. The On-Premise Poller sends data collection files at the following rate:
| Sync frequency | One file every 30 seconds |
|---|
| Maximum data points per file | 50 |
| Maximum zip file size | 150 KB |
| Parallel upload threads | 10 (default) |
| Sync scalability | Up to 1,200 files per hour (10 parallel threads × 120 files per hour each) |
Network monitoring data
| Devices per file | 10 |
|---|
| Maximum zip file size per report | 1.5 MB |
| Upload time per file | Up to 30 seconds |
| Parallel upload threads | Five (default) |
| Sync scalability | Up to 600 files per hour |
Related articles
Related Articles
On-Premise Poller Scalability and Capacity Guidelines
As your organization grows, you can scale your monitoring environment by adding On-Premise Pollers and distributing monitoring workloads across them. This article explains how On-Premise Poller capacity scales, how On-Premise Poller Groups distribute ...
Troubleshooting steps if the data collection stops for a network device
Case 1: The On-Premise Poller is Down and/or the Network Module is Disabled. Go to Admin > On-Premise Poller. Check if the state of the On-Premise Poller is active. If not, activate it. Check if the status of the On-Premise Poller is up. If it's ...
Data collection behavior for network devices in the high availability setup for On-Premise Pollers
When high availability (HA) is configured for On-Premise Pollers in Site24x7, it ensures continued data collection during a primary On-Premise Poller failure. However, some differences in data collection behavior may be observed when the secondary ...
How to set up alerts for network device data collection issues
When your network monitoring interfaces are not collecting data due to issues in the Network Module, you'll want to be alerted. To set up alerts, you need to add or edit the threshold and availability profile of the On-Premise Poller, which is used ...
How secure is On-Premise Poller
On-Premise Poller: Introduction On-Premise Poller, a lightweight agent, helps to monitor your internal network and resources behind a firewall or virtual private network (VPN). You can install On-Premise Poller in various branch offices within a ...